![]() If the system must start on boot up without a network connection you can set a static IP. Note: If your controller is set to obtain its IP address from a DHCP server, the EXE will only launch when the controller is able to obtain a valid IP address.Open Network Settings, and assign a static IP address.Open System Settings, and disable Halt on IP failure.Detect the device under Remote Systems in National Instruments Measurement & Automation Explorer (MAX).To set a static IP address for your controller:.Note: This is only relevant for Phar Lap ETS and VxWorks controllers.If the device in question is not connected to a network, the device should not be set to obtain an IP address from DHCP server. Check the manual for your device to determine the method your device uses. Some devices use hardware DIP switches, while others use the configuration set in System Settings for the device in NI MAX.Ensure Disable RT Startup App is not selected in NI MAX under the target's System Settings,.If this switch is in the "ON" position, LabVIEW Real-Time will not run the EXE automatically. Some real-time controllers have a physical DIP switch that controls a feature usually referred to as "NOAPP", or no application mode.If applicable, locate the hardware DIP switch, change it to the 'off' position, and reboot the controller.Check your device manual to determine if you have a NOAPP DIP switch, and if so, ensure that the Physical NOAPP DIP switch is set to 'OFF.'.Figure 1: Set Application as Startup in the LabVIEW Project ![]()